9.99A 30V 60W Constant Current Electronic Load Discharge Battery Capacity Tester

9.99A 30V 60W Constant Current Electronic Load Discharge Battery Capacity Tester

SKU:050915
Regular price $19.99

HTB1ZYSui4PI8KJjSspoq6x6MFXaU

Features:
Note: This product is a professional testing equipment , requiring the user must have some basic electronic ( example: Users should understand what is the meaning of the voltage and current capacity Ah , etc.), or you may be unable to properly use the device, possibly mishandled cause unnecessary damage caused by the test device loss !
Power supply requirement : DC12V voltage ( actual voltage 11-14V)
current is not less than 0.5A of power, or the power will be displayed inappropriate Err6.
Note: The default power adapter is not included.
Operating modes: single mode constant current (CC)
Discharge current : 0.20-9.99A stepper 0.1A or0.01A
Discharge current maximum error : 0.7% -0.01A
The maximum capacity test error : 0.5A 2.5%, 2A 1.5%, 5A and above 1.2%
Offline ( termination ) Voltage Range : 1.0-25.0V stepping 1V or 0.1V
Discharge voltage : 1.00-30.00V
The maximum voltage measurement error : 1% + - 0.02V
Maximum power : 60W super power automatically limits the maximum current (for example, up to 60W when it can open 9.99A 6V and 20V maximum at the only open 3.00A)
Highest battery test statistic : 999.9Ah or 9999Wh, achieve value stop testing ( first value to those who stop condition )
Board size : 60W 100mm * 70mm * 57mm ( fan prominent board about 12mm)
Positioning hole locations : 60mm * 88mm diameter 3.2mm 5mm pedestal already installed.
Fan control : intelligent fan control ( according to the radiator fan can be infinitely variable automatic temperature )
Protection: Overheat protection "otP"; transient overpower protection "oPP"; overpressure protection "ouP"; reverse polarity protection; power supply voltage abnormal protection.
Setting Digital Illustration:
II: Electronic Load mode:
1. Turn on the power supply 12V boot into electronic load mode , ensuring in a stopped state ("RUN" does not light, otherwise the press of the start-stop switch to turn off the load ) connected to the power supply under test to the test port input power (P + P - ) , pay attention not to take the wrong polarity !
2. Set current and lower voltage knob , turn the knob to set the value of the current setting position , then press the knob to change the setting digit, digital middle two digits to the right of the indicator and digital indicator VA simultaneously determine the current set position .
3. Press the start-stop switch , load began to run , "RUN" lights , power is applied to the circuit under test is set to enter the discharge current , while the upper display the actual input load voltage , when the voltage drops below the set limit voltage " RUN " LED flashes and short beep alarm buzzer accompanied.
4. The test procedure can be modified at any current , and if you need to modify the lower voltage to stop the load can modify .
Note:When in alarm state , can only transfer a small current does not increase !Tester automatic power-down feature to save enough to save the set parameters and run state, when the state again after power transmission will complete before the power failure and restore data.
The battery capacity test mode:
1. The test battery should be fully charged with a special charger !
2. Give the tester is powered into the battery capacity test mode, connect the battery current line to P + P- positive and negative terminals , if you use four-wire clamp test, while the four-wire interface to the positive and negative voltage test fixture is connected to V + V - port.
3. Turn the knob to set the discharge current and discharge voltage ( referring to two specific methods : 2 Description ) , one press after setting the start and stop switch , a battery tester and a first line detection, automatic identification 2-4 line ( 2-wire line identification presentation JS-2,4 identification JS-4, if an error please stop the test and check the wiring ) , then enter the test , if the fault code appears , refer to later explain .
The testing process will round up digital noticeable battery voltage , current , and the current discharge capacity Ah discharge energy Wh, when the discharge end ( battery voltage is below the set voltage ) , the tester displays the data stays in Ah and blink rapidly , with bee shortness buzzer alarm.
5. Press the start and stop at the knob or switch to stop the alarm , you can turn the knob to view the battery discharge data , including discharge capacity Ah, Wh and discharge energy platform voltage V, start-stop button is pressed again, clear the data back to the initial setting interface before testing the next section batteries.
Additional information:
1. Battery test process can adjust the discharge current, if you need to re- adjust the termination voltage, you can pause by pressing the switch at the start and stop the discharge modification ( pause discharge will return to the settings page, this time discharge data is not lost, if necessary, you can long press clears the data until the start-stop

HTB1jCuMiY_I8KJjy1Xaq6zsxpXaS

050915 (1)050915 (2)050915 (3)050915 (4)050915 (5)050915 (6)050915 (7)050915 (9)

HTB1CoFQi_TI8KJjSsphq6AFppXax

HTB1hs.8XfvsK1RjSspdq6AZepXaz
trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancy86-0755-85201155

HTB1ZYSui4PI8KJjSspoq6x6MFXaU

Features:
Note: This product is a professional testing equipment , requiring the user must have some basic electronic ( example: Users should understand what is the meaning of the voltage and current capacity Ah , etc.), or you may be unable to properly use the device, possibly mishandled cause unnecessary damage caused by the test device loss !
Power supply requirement : DC12V voltage ( actual voltage 11-14V)
current is not less than 0.5A of power, or the power will be displayed inappropriate Err6.
Note: The default power adapter is not included.
Operating modes: single mode constant current (CC)
Discharge current : 0.20-9.99A stepper 0.1A or0.01A
Discharge current maximum error : 0.7% -0.01A
The maximum capacity test error : 0.5A 2.5%, 2A 1.5%, 5A and above 1.2%
Offline ( termination ) Voltage Range : 1.0-25.0V stepping 1V or 0.1V
Discharge voltage : 1.00-30.00V
The maximum voltage measurement error : 1% + - 0.02V
Maximum power : 60W super power automatically limits the maximum current (for example, up to 60W when it can open 9.99A 6V and 20V maximum at the only open 3.00A)
Highest battery test statistic : 999.9Ah or 9999Wh, achieve value stop testing ( first value to those who stop condition )
Board size : 60W 100mm * 70mm * 57mm ( fan prominent board about 12mm)
Positioning hole locations : 60mm * 88mm diameter 3.2mm 5mm pedestal already installed.
Fan control : intelligent fan control ( according to the radiator fan can be infinitely variable automatic temperature )
Protection: Overheat protection "otP"; transient overpower protection "oPP"; overpressure protection "ouP"; reverse polarity protection; power supply voltage abnormal protection.
Setting Digital Illustration:
II: Electronic Load mode:
1. Turn on the power supply 12V boot into electronic load mode , ensuring in a stopped state ("RUN" does not light, otherwise the press of the start-stop switch to turn off the load ) connected to the power supply under test to the test port input power (P + P - ) , pay attention not to take the wrong polarity !
2. Set current and lower voltage knob , turn the knob to set the value of the current setting position , then press the knob to change the setting digit, digital middle two digits to the right of the indicator and digital indicator VA simultaneously determine the current set position .
3. Press the start-stop switch , load began to run , "RUN" lights , power is applied to the circuit under test is set to enter the discharge current , while the upper display the actual input load voltage , when the voltage drops below the set limit voltage " RUN " LED flashes and short beep alarm buzzer accompanied.
4. The test procedure can be modified at any current , and if you need to modify the lower voltage to stop the load can modify .
Note:When in alarm state , can only transfer a small current does not increase !Tester automatic power-down feature to save enough to save the set parameters and run state, when the state again after power transmission will complete before the power failure and restore data.
The battery capacity test mode:
1. The test battery should be fully charged with a special charger !
2. Give the tester is powered into the battery capacity test mode, connect the battery current line to P + P- positive and negative terminals , if you use four-wire clamp test, while the four-wire interface to the positive and negative voltage test fixture is connected to V + V - port.
3. Turn the knob to set the discharge current and discharge voltage ( referring to two specific methods : 2 Description ) , one press after setting the start and stop switch , a battery tester and a first line detection, automatic identification 2-4 line ( 2-wire line identification presentation JS-2,4 identification JS-4, if an error please stop the test and check the wiring ) , then enter the test , if the fault code appears , refer to later explain .
The testing process will round up digital noticeable battery voltage , current , and the current discharge capacity Ah discharge energy Wh, when the discharge end ( battery voltage is below the set voltage ) , the tester displays the data stays in Ah and blink rapidly , with bee shortness buzzer alarm.
5. Press the start and stop at the knob or switch to stop the alarm , you can turn the knob to view the battery discharge data , including discharge capacity Ah, Wh and discharge energy platform voltage V, start-stop button is pressed again, clear the data back to the initial setting interface before testing the next section batteries.
Additional information:
1. Battery test process can adjust the discharge current, if you need to re- adjust the termination voltage, you can pause by pressing the switch at the start and stop the discharge modification ( pause discharge will return to the settings page, this time discharge data is not lost, if necessary, you can long press clears the data until the start-stop

HTB1jCuMiY_I8KJjy1Xaq6zsxpXaS

050915 (1)050915 (2)050915 (3)050915 (4)050915 (5)050915 (6)050915 (7)050915 (9)

HTB1CoFQi_TI8KJjSsphq6AFppXax

HTB1hs.8XfvsK1RjSspdq6AZepXaz

Purchasing & Delivery

Before you make your purchase, it’s helpful to know the measurements of the area you plan to place the furniture. You should also measure any doorways and hallways through which the furniture will pass to get to its final destination.
Picking up at the store
Shopify Shop requires that all products are properly inspected BEFORE you take it home to insure there are no surprises. Our team is happy to open all packages and will assist in the inspection process. We will then reseal packages for safe transport. We encourage all customers to bring furniture pads or blankets to protect the items during transport as well as rope or tie downs. Shopify Shop will not be responsible for damage that occurs after leaving the store or during transit. It is the purchaser’s responsibility to make sure the correct items are picked up and in good condition.
Delivery
Customers are able to pick the next available delivery day that best fits their schedule. However, to route stops as efficiently as possible, Shopify Shop will provide the time frame. Customers will not be able to choose a time. You will be notified in advance of your scheduled time frame. Please make sure that a responsible adult (18 years or older) will be home at that time.
In preparation for your delivery, please remove existing furniture, pictures, mirrors, accessories, etc. to prevent damages. Also insure that the area where you would like your furniture placed is clear of any old furniture and any other items that may obstruct the passageway of the delivery team. Shopify Shop will deliver, assemble, and set-up your new furniture purchase and remove all packing materials from your home. Our delivery crews are not permitted to move your existing furniture or other household items. Delivery personnel will attempt to deliver the purchased items in a safe and controlled manner but will not attempt to place furniture if they feel it will result in damage to the product or your home. Delivery personnel are unable to remove doors, hoist furniture or carry furniture up more than 3 flights of stairs. An elevator must be available for deliveries to the 4th floor and above.