110V 220V 12V 24V Dual Digital Temperature Controller Thermostat

110V 220V 12V 24V Dual Digital Temperature Controller Thermostat

SKU:X13344
Regular price $12.00 Sale price $5.99

AC 110V 220V 12V 24V Dual Digital Temperature Controller Thermostat Thermometer Home Incubator Heating Cooling Thermal Regulator

This is a dual display and dual control temperature controller,it can both control refrigeration or heating of two products, setting method is same of left and right.

Specifications:

Working Voltage: DC 12V / DC 24V / AC 220V
Sensor model: NTC(10K/3435)
Working current:Max 200Ma
Date Storage: available.
Working temperature:0℃~50℃
Storage temperature:-10℃~60℃
Temperature control range:-50℃~110℃
Temperature measurement error:±0.5℃
Meter length:76x55x31mm
Hole size:70x50mm(LxH)
Sensor probe length: 1M

Menu code description:



Set the left control temperature
Press the “SET”Key board and left screen flashes.Press “UP” and “ Down “key board to adjust temperature range,press right “UP” or “Down”key board (Any one) to preserve then exit.
Set the right control temperature
Press twice “SET”board and right screen flashes, Press”UP” and “Down”Key board to adjust temperature,press right “UP” and “Down”board(any one) to preserve then exit.
Start and stop timing
Under the state of standby electric to press the “SET” once, start timing output ,screen alternately.
Press the “SET” Key board three seconds enter into the setting of control parameters.
Press ▲or ▼ key board choose adjust menu . then press SET key board once again to enter into the related state of control parameter setting, press ▲or ▼ key board to adjust parameters which requires modify. Press “SET” key board to exit after adjusted ,or exited from delayed 6 seconds system.

◆Cooling .heating mode setting

Press ”SET” key board less than 3 seconds ,enter into menu display, the code “HC” is displaying on screen, press “set” key board displayed working mode.Press”▲” or “▼”to adjust parameters .”C” means cooling mode ,”H” means heating mode.

◆Return difference function

Maximum temperature was restricted with return difference between start up and close down.

◆Return difference setting.

Press ”SET” key board less than 3 seconds, enter into the menu display, press “▲” or “▼” key board to adjust code until screen displayed “D” code, press “SET” keyboard to displayed value of return difference. Press the “▲” and “▼” keyboard again to adjust parameters.

◆Temperature correction function

When there has deviations between measurement temperature and standard temperature. Machine measurement value and standard temperature can adjust to same under function of temperature correction. Temperature after correction=Temperature before correction +value of correction (Value of correction can be positive number ,negative number and zero)

◆Temperature correction setting.

Press ”SET” keyboard less than 3 seconds, enter into menu display, press “▲” or “▼” keyboard to adjust code until screen displayed “CA”, press ”SET” keyboard display temperature correction value, Press the “▲” and “▼” keyboard again to adjust parameters.

◆Delay protection function:

Press ”SET” Keyboard less than 3 minutes .enter into the menu display . press “▲” or “▼” keyboard to adjust code until screen displayed “PT”, Press “SET” keyboard displayed delay protection setting,Press the “▲” and “▼”keyboard again to adjust parameters.

◆Ultra-temperature alarm function

If measurement temperature ≥control temperature +AH alarm relay actuated , temperature controller alarming ,display screen alternated displaying “H” and present temperature. Then press anyone keyboards to stop alarming and turn off alarm relay output

◆Ultra-temperature alarm setting

Press “    SET” keyboard less than 3 seconds , enter into menu display,press “▲” or “▼” keyboard to adjust code until screen displayed “HS” .Press ‘SET” keyboard displayed the set value of ultra-temperature, press  “▲” or “▼”keyboard again to adjust parameters , Set up “HS as “0”,you can turn off the alarm function.

◆Ultralow temperature alarm function

measurement temperature < control temperature-LS alarm relay actuated ,

temperature controller alerting . Display screen alternated displaying “L ”and present temperature ,press anyone keyboard and turn off relay output.

◆Ultralow temperature alarm setting

Press “SET” keyboard less than 3 seconds ,enter into menu display,press “▲” or “▼” keyboard to adjust code until screen displayed “LS”, press ”SET” keyboard displayed the set value of ultralow temperature, press  “▲” or “▼” keyboard again to adjust parameters ,Set up “LS” as “0”,you can turn off the alarm function.

Status of the Indicator light introduction.

Green means working indicator light , green light long bright means state of cooling or heating. Red light flicking means delay to start up and it with function of setting.Red light long bright means in state of setting.

Press “SET” 3 seconds enter into system high ranking menu setting .During the progress of setting ,press “▲” or “▼” keyboard to choose menu which need to adjust.Then press “SET” keyboard once again enter into state of related controller parameters setting,,press “▲” or “▼” keyboard to adjust the controller parameters which need to modify,Exited by press ”SET” keyboard after adjustment.Temperature controller restart automatically.

Disturbance Display.
When sensor disconnected, screen displaying “LLL”
When sensor detectedtemperaturebelow measurement range,screen displaying EEE”
When sensor detected temperature higher than measurement range ,screen displaying “HHH”

7.Caution

◆ Connect to the correct working voltage ,machine is regular working within the range of ±10%standard input voltage

◆Connect to the power load less than maximum control power of temperature controller. If exceed please using with AC contactor.

◆Connect to the correct power source ,load, sensor , temperature controller will damaged after connected to wrong wire.

Please don’t make the wire of sensor and power wires parallel connection.

trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancy86-0755-85201155

AC 110V 220V 12V 24V Dual Digital Temperature Controller Thermostat Thermometer Home Incubator Heating Cooling Thermal Regulator

This is a dual display and dual control temperature controller,it can both control refrigeration or heating of two products, setting method is same of left and right.

Specifications:

Working Voltage: DC 12V / DC 24V / AC 220V
Sensor model: NTC(10K/3435)
Working current:Max 200Ma
Date Storage: available.
Working temperature:0℃~50℃
Storage temperature:-10℃~60℃
Temperature control range:-50℃~110℃
Temperature measurement error:±0.5℃
Meter length:76x55x31mm
Hole size:70x50mm(LxH)
Sensor probe length: 1M

Menu code description:



Set the left control temperature
Press the “SET”Key board and left screen flashes.Press “UP” and “ Down “key board to adjust temperature range,press right “UP” or “Down”key board (Any one) to preserve then exit.
Set the right control temperature
Press twice “SET”board and right screen flashes, Press”UP” and “Down”Key board to adjust temperature,press right “UP” and “Down”board(any one) to preserve then exit.
Start and stop timing
Under the state of standby electric to press the “SET” once, start timing output ,screen alternately.
Press the “SET” Key board three seconds enter into the setting of control parameters.
Press ▲or ▼ key board choose adjust menu . then press SET key board once again to enter into the related state of control parameter setting, press ▲or ▼ key board to adjust parameters which requires modify. Press “SET” key board to exit after adjusted ,or exited from delayed 6 seconds system.

◆Cooling .heating mode setting

Press ”SET” key board less than 3 seconds ,enter into menu display, the code “HC” is displaying on screen, press “set” key board displayed working mode.Press”▲” or “▼”to adjust parameters .”C” means cooling mode ,”H” means heating mode.

◆Return difference function

Maximum temperature was restricted with return difference between start up and close down.

◆Return difference setting.

Press ”SET” key board less than 3 seconds, enter into the menu display, press “▲” or “▼” key board to adjust code until screen displayed “D” code, press “SET” keyboard to displayed value of return difference. Press the “▲” and “▼” keyboard again to adjust parameters.

◆Temperature correction function

When there has deviations between measurement temperature and standard temperature. Machine measurement value and standard temperature can adjust to same under function of temperature correction. Temperature after correction=Temperature before correction +value of correction (Value of correction can be positive number ,negative number and zero)

◆Temperature correction setting.

Press ”SET” keyboard less than 3 seconds, enter into menu display, press “▲” or “▼” keyboard to adjust code until screen displayed “CA”, press ”SET” keyboard display temperature correction value, Press the “▲” and “▼” keyboard again to adjust parameters.

◆Delay protection function:

Press ”SET” Keyboard less than 3 minutes .enter into the menu display . press “▲” or “▼” keyboard to adjust code until screen displayed “PT”, Press “SET” keyboard displayed delay protection setting,Press the “▲” and “▼”keyboard again to adjust parameters.

◆Ultra-temperature alarm function

If measurement temperature ≥control temperature +AH alarm relay actuated , temperature controller alarming ,display screen alternated displaying “H” and present temperature. Then press anyone keyboards to stop alarming and turn off alarm relay output

◆Ultra-temperature alarm setting

Press “    SET” keyboard less than 3 seconds , enter into menu display,press “▲” or “▼” keyboard to adjust code until screen displayed “HS” .Press ‘SET” keyboard displayed the set value of ultra-temperature, press  “▲” or “▼”keyboard again to adjust parameters , Set up “HS as “0”,you can turn off the alarm function.

◆Ultralow temperature alarm function

measurement temperature < control temperature-LS alarm relay actuated ,

temperature controller alerting . Display screen alternated displaying “L ”and present temperature ,press anyone keyboard and turn off relay output.

◆Ultralow temperature alarm setting

Press “SET” keyboard less than 3 seconds ,enter into menu display,press “▲” or “▼” keyboard to adjust code until screen displayed “LS”, press ”SET” keyboard displayed the set value of ultralow temperature, press  “▲” or “▼” keyboard again to adjust parameters ,Set up “LS” as “0”,you can turn off the alarm function.

Status of the Indicator light introduction.

Green means working indicator light , green light long bright means state of cooling or heating. Red light flicking means delay to start up and it with function of setting.Red light long bright means in state of setting.

Press “SET” 3 seconds enter into system high ranking menu setting .During the progress of setting ,press “▲” or “▼” keyboard to choose menu which need to adjust.Then press “SET” keyboard once again enter into state of related controller parameters setting,,press “▲” or “▼” keyboard to adjust the controller parameters which need to modify,Exited by press ”SET” keyboard after adjustment.Temperature controller restart automatically.

Disturbance Display.
When sensor disconnected, screen displaying “LLL”
When sensor detectedtemperaturebelow measurement range,screen displaying EEE”
When sensor detected temperature higher than measurement range ,screen displaying “HHH”

7.Caution

◆ Connect to the correct working voltage ,machine is regular working within the range of ±10%standard input voltage

◆Connect to the power load less than maximum control power of temperature controller. If exceed please using with AC contactor.

◆Connect to the correct power source ,load, sensor , temperature controller will damaged after connected to wrong wire.

Please don’t make the wire of sensor and power wires parallel connection.

Purchasing & Delivery

Before you make your purchase, it’s helpful to know the measurements of the area you plan to place the furniture. You should also measure any doorways and hallways through which the furniture will pass to get to its final destination.
Picking up at the store
Shopify Shop requires that all products are properly inspected BEFORE you take it home to insure there are no surprises. Our team is happy to open all packages and will assist in the inspection process. We will then reseal packages for safe transport. We encourage all customers to bring furniture pads or blankets to protect the items during transport as well as rope or tie downs. Shopify Shop will not be responsible for damage that occurs after leaving the store or during transit. It is the purchaser’s responsibility to make sure the correct items are picked up and in good condition.
Delivery
Customers are able to pick the next available delivery day that best fits their schedule. However, to route stops as efficiently as possible, Shopify Shop will provide the time frame. Customers will not be able to choose a time. You will be notified in advance of your scheduled time frame. Please make sure that a responsible adult (18 years or older) will be home at that time.
In preparation for your delivery, please remove existing furniture, pictures, mirrors, accessories, etc. to prevent damages. Also insure that the area where you would like your furniture placed is clear of any old furniture and any other items that may obstruct the passageway of the delivery team. Shopify Shop will deliver, assemble, and set-up your new furniture purchase and remove all packing materials from your home. Our delivery crews are not permitted to move your existing furniture or other household items. Delivery personnel will attempt to deliver the purchased items in a safe and controlled manner but will not attempt to place furniture if they feel it will result in damage to the product or your home. Delivery personnel are unable to remove doors, hoist furniture or carry furniture up more than 3 flights of stairs. An elevator must be available for deliveries to the 4th floor and above.