Real-time Relay Module Timing Switch Control Synchronization Delay Timer

Real-time Relay Module Timing Switch Control Synchronization Delay Timer

SKU:100030
Regular price $7.99

Real-time relay timing and clock synchronization time control delay 24H timing 5 time periods
Product Highlights:
  • Wide voltage power supply 5.0V ~ 60V;
  • A mode can be set for multiple time periods, can reach 5 time periods;
  • With a buzzer alarm function.
Mode introduction:
  • OPE: relay closing time point, CLE: relay off time point
  • Time period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time period)
  • ----: function shielding
  • P-1: The relay closes or outputs pulses every day to the OPE time point, and the relay turns off or outputs pulses to the CLE time point.
  •  
  • P-2: set the day, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay disconnect / or output pulse
  •  
  • P-3: set the date of the month, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay is off or output pulse
  •  
  • P-4: Set the date 1 to date 2, start every day at the OPE time point, end to the CLE time point, relay action or output pulse
  •  
  • P-5: As with P-4, only the month can not be set
First, how to set the time?
  • In the time to run the interface, press the DOWN button for a while: 
  • Step 1: Select the time period: PE-1 ~ PE-5 Press UP and DOWN to select; 
  • Step 2: Press the SET key to select the mode: P-1 ~ P-5 (Set this time period to the corresponding mode) by pressing the UP and DOWN keys. ("----" means to block this time period) 
  • Note: Each time period can be repeated from the "----", P-1 ~ P-5 one of the optional; For example,you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode, time period 2 work in P-2 mode and so on.
  • Step 3: After the mode selection is finished, press the SET key to enter the time period setting interface, set the interface in the time period, press the SET key to switch the parameter, "OPE" start time point, "CLE" end point, "dAE" date information;
  • Step 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to release, automatically check whether the parameter settings are legal, legal to save the parameters, return to the time to run the interface; if the parameter is wrong, "ERR" reminder (for example, stop time or Date <= start time or date), return to the parameter setting interface;
  • Additional features: Each "time period" can be set individually
In the specific parameter setting interface (after the second step), press the STOP button to switch the output mode:
  • OUT1: Start time point turns on the relay, the end time is off the relay
  • OUT2: Outputs 1S pulse to start or end time
In the specific parameter setting interface (after the second step), press the STOP button for a while to switch the ringing mode:
  • BLL0: Ring disable
  • BLL1: Ring enable
  • Note: When the bell rings, press any button to stop the ring 
STOP key function expansion:
  • Relay enable mode:
  • ON: enable relay on;
  •  OFF: Do not turn on the relay, it is always off;
  • Press the STOP button on the time display interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is the emergency stop function, press once to close the closed relay) 
  • After the relay is disabled, the product can be used as an alarm clock. 
Sleep mode:
  • C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation; 
  • O-d normal mode: digital tube is always open display;
  • Press the STOP button for a while after 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.
Package Included:
  • 1Pcs  x Real-time relay Module(Note: Not including batteries)
trust seal
  • guaranteeQuality checked
  • Special gift cardsSpecial gift cards
  • Free return Within 60 days
  • Consultancy86-0755-85201155
Real-time relay timing and clock synchronization time control delay 24H timing 5 time periods
Product Highlights:
  • Wide voltage power supply 5.0V ~ 60V;
  • A mode can be set for multiple time periods, can reach 5 time periods;
  • With a buzzer alarm function.
Mode introduction:
  • OPE: relay closing time point, CLE: relay off time point
  • Time period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time period)
  • ----: function shielding
  • P-1: The relay closes or outputs pulses every day to the OPE time point, and the relay turns off or outputs pulses to the CLE time point.
  •  
  • P-2: set the day, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay disconnect / or output pulse
  •  
  • P-3: set the date of the month, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay is off or output pulse
  •  
  • P-4: Set the date 1 to date 2, start every day at the OPE time point, end to the CLE time point, relay action or output pulse
  •  
  • P-5: As with P-4, only the month can not be set
First, how to set the time?
  • In the time to run the interface, press the DOWN button for a while: 
  • Step 1: Select the time period: PE-1 ~ PE-5 Press UP and DOWN to select; 
  • Step 2: Press the SET key to select the mode: P-1 ~ P-5 (Set this time period to the corresponding mode) by pressing the UP and DOWN keys. ("----" means to block this time period) 
  • Note: Each time period can be repeated from the "----", P-1 ~ P-5 one of the optional; For example,you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode, time period 2 work in P-2 mode and so on.
  • Step 3: After the mode selection is finished, press the SET key to enter the time period setting interface, set the interface in the time period, press the SET key to switch the parameter, "OPE" start time point, "CLE" end point, "dAE" date information;
  • Step 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to release, automatically check whether the parameter settings are legal, legal to save the parameters, return to the time to run the interface; if the parameter is wrong, "ERR" reminder (for example, stop time or Date <= start time or date), return to the parameter setting interface;
  • Additional features: Each "time period" can be set individually
In the specific parameter setting interface (after the second step), press the STOP button to switch the output mode:
  • OUT1: Start time point turns on the relay, the end time is off the relay
  • OUT2: Outputs 1S pulse to start or end time
In the specific parameter setting interface (after the second step), press the STOP button for a while to switch the ringing mode:
  • BLL0: Ring disable
  • BLL1: Ring enable
  • Note: When the bell rings, press any button to stop the ring 
STOP key function expansion:
  • Relay enable mode:
  • ON: enable relay on;
  •  OFF: Do not turn on the relay, it is always off;
  • Press the STOP button on the time display interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is the emergency stop function, press once to close the closed relay) 
  • After the relay is disabled, the product can be used as an alarm clock. 
Sleep mode:
  • C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation; 
  • O-d normal mode: digital tube is always open display;
  • Press the STOP button for a while after 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.
Package Included:
  • 1Pcs  x Real-time relay Module(Note: Not including batteries)

Purchasing & Delivery

Before you make your purchase, it’s helpful to know the measurements of the area you plan to place the furniture. You should also measure any doorways and hallways through which the furniture will pass to get to its final destination.
Picking up at the store
Shopify Shop requires that all products are properly inspected BEFORE you take it home to insure there are no surprises. Our team is happy to open all packages and will assist in the inspection process. We will then reseal packages for safe transport. We encourage all customers to bring furniture pads or blankets to protect the items during transport as well as rope or tie downs. Shopify Shop will not be responsible for damage that occurs after leaving the store or during transit. It is the purchaser’s responsibility to make sure the correct items are picked up and in good condition.
Delivery
Customers are able to pick the next available delivery day that best fits their schedule. However, to route stops as efficiently as possible, Shopify Shop will provide the time frame. Customers will not be able to choose a time. You will be notified in advance of your scheduled time frame. Please make sure that a responsible adult (18 years or older) will be home at that time.
In preparation for your delivery, please remove existing furniture, pictures, mirrors, accessories, etc. to prevent damages. Also insure that the area where you would like your furniture placed is clear of any old furniture and any other items that may obstruct the passageway of the delivery team. Shopify Shop will deliver, assemble, and set-up your new furniture purchase and remove all packing materials from your home. Our delivery crews are not permitted to move your existing furniture or other household items. Delivery personnel will attempt to deliver the purchased items in a safe and controlled manner but will not attempt to place furniture if they feel it will result in damage to the product or your home. Delivery personnel are unable to remove doors, hoist furniture or carry furniture up more than 3 flights of stairs. An elevator must be available for deliveries to the 4th floor and above.